Foot Step ( Single)
Full Fowler Bed
HeartStart XL+ Defibrillator/monitor
-
Battery Type -
Rechargeable, lithium ion; see battery label for capacity information
Dimensions -
1˝ high x 4.5˝ wide x 5.7˝ long (23.6 mm high x 116 mm wide x 146 mm long)
Capacity -
With a new fully charged battery, at 20 °C (68 °F) one of the following: At least 3 hours of monitoring (ECG and SpO2 monitored continuously and NBP sampled every 15 minutes) followed by 20 full-energy charge/shocks. OR at least two hours of pacing (180ppm at 140mA with 40 msec pulse width) while monitoring (ECG and SpO2 monitored continuously and NBP sampled every 15 minutes) followed by 20 full-energy charge/shocks; OR at least 175 full energy charge/shocks
Weight -
Approximately 1.5 lbs (0.68kg)
Charge time device off -
With the temperature between 0-35° C (32-95° F) less than 3 hours to 100% capacity and less than 2 hours to 80% capacity
Life -
Approximately 3 year(s)
Battery indicators -
Battery gauge on battery, capacity indicator on display, power indicators on front of device; flashing RFU indicator, chirp and Low Battery messages on the display for low battery condition. When a low battery message first appears there is still enough energy for at least 10 minutes of monitoring and 6 maximum energy discharges
Battery storage -
Storing the battery for extended periods at temperatures above 40° C (104° F) reduces battery capacity and degrades battery life
-
-
Physical dimensions Weight -
Weight 14.7 lbs (6.6 kg), includes one battery/one new roll of paper/one pads cable. Incremental weight of external standard paddles and paddle tray is less than 3 lbs (1.3 kg)
Standard operator position -
Within one meter (3 feet) of the device
-
-
Physical dimensions Defibrillator Model HeartStart XL+ Size -
Size 9˝ high x 11.6˝ wide x 10.9˝ deep (23 cm x 29.6 cm x 27.9 cm)
-
-
Power supply Type -
Rechargeable lithium ion battery; AC power using a protectively grounded outlet
-
-
Printer Continuous ECG strip -
The Print button starts and stops the strip. The printer can be configured to be run real time or with a 10-second delay. The strip prints the primary ECG lead and a second wave with event annotations and measurements
Auto printing -
The printer can be configured to automatically print on Mark Events, Charge, Shock, and Alarm
Reports -
The following can be printed: Event Summary (Long or Short)/Vital Signs Trends/Operational Check/Configuration/Status Log/Device Information
Speed -
25 mm/s with an accuracy of +/-5% mm/s
Amplitude accuracy -
5% for offset voltages of +/- 300 mV at 5Hz
Paper size -
50 mm wide x 30 m long
-
-
Display Size -
Approximately 6.5″ (16.5 cm) diagonal viewing area
Resolution -
640 x 480 pixels (VGA) with 32 brightness levels per color
Type -
Approximately 6.5″ (16.5 cm) diagonal viewing area
Sweep speed -
20 mm/s nominal (stationary trace; sweeping erase bar) for ECG and SpO2 mm/s
Wave viewing time -
5.2 s
-
-
Environmental Operating temperature -
0°C to 45°C (32°F to 113°F)
Humidity -
Up to 95 RH
Storage temperature -
20°C to 70°C (-4°F to 158°F)
Atmospheric pressure range -
Operating and storage – 1014 mbar to 572 mbar(0 to 15000 ft; 0 to 4500 m)
Shock(a) -
Operating Half-sine waveform/duration ≤11 ms/acceleration ≥ 15.3 G at 3 shocks per face
Shock(b) -
Non-operating Trapezoidal waveform/acceleration 30G/ velocity change 7.42 m/s +/-10% 1 shock per face
Water/solids ingress resistance -
Meets Ingress Protection level IP21
EMC -
Complies with the requirements of standard EN 60601-1-2:2002
Safety -
Meets UL 60601-1 (1st edition)/EN 60601-2-4:2003/EN 60601-1:1990
Mode of operation -
Continuous
AC Line powered -
100-240 VAC/50 or 60 Hz/1-0.46A/Class I Equipment
Battery powered -
Minimum 14.4 V rechargeable lithium ion VAC/Hz
-
-
Defibrillator Waveform -
Biphasic Truncated Exponential. Waveform parameters adjusted as a function of patient impedance
Shock series -
Configurable energy escalation in a series
Charge time -
3 seconds to the recommended adult energy level (150 Joules) with a new fully-charged battery installed
-
Less than 5 seconds to the selected energy level (up to 200 Joules) with a new fully charged battery installed
-
The device powers on in manual defibrillation mode ready to deliver shock in less than 8 seconds plus applicable charge time assuming an immediate selection of an energy and initiation of a charge even at 90V AC and after 15 maximum energy discharges
-
The device powers on in AED mode ready to deliver shock in less than 17 seconds plus applicable charge time
Shock delivery -
Via multifunction electrode pads or paddles
Leads sensing -
Leads off sensing and PCI sensing for pads/paddles. Apply 500nA rms (571Hz); 200uA rms (32KHz)
Minimum patient impedance range -
25 ohm (external defibrillation);15 ohm (internal defibrillation) ohm
Maximum patient impedance range -
250 ohm. Actual functional range may exceed these values ohm
-
ICU Bed 5 Function
Infusion Pump ( Infuse Max)
| Model Name/Number | INFUMAX |
| Product Type | Volumetric Infusion Pump |
| Usage/Application | Hospital |
| Weight | 5.5kg |
| Display | LCD And 7 Segment LED Display |
| Power Supply Range | AC 220 to 240 V |
| Battery Backup Range | 4hrs @ 8 drop/min or 25 ml/hr (Auto Power Saving Mode) |
| Power Consumption | 10 V A(W) |
| Pumping Mechanism | Linear Peristaltic |
| Drop Sensors | External |
| ‘Air in line’ Detector | Internal |
| Dimensions | 140x145x200mm |
| Certification | CE, ISO13485:2016, ISO 9001:2008 |
| Accuracy | +/- 5% |
| Battery Charging Period | 16 hrs Automatic |
| Availability | In Stock |
Infusion Set Hitech
Instrument Trolley MS
Instrument Trolley MS
Introducer (PUNCTURE) Needle
Excess™ Vascular Access Kits w/Standard Co-axial Introducer (Box of 10)
SHEATH NEEDLE
GAUGE x LENGTH
ECHOGENIC
DILATOR
STIFFNESS LOCKING NUT
COLOR
GUIDEWIRE
DIAMETER x LENGTH
CATALOG # SIZE MATERIAL
391504300E 4F 21G x 7cm Yes Standard Red .018” x 40cm NT
391505000E 5F 21G x 7cm Yes Standard Red .018” x 40cm SS
391505300E 5F 21G x 7cm Yes Standard Red .018” x 40cm NT
391505400E 5F 21G x 7cm No Standard Red .018” x 40cm NT
Excess™ Vascular Access Kits w/Stiff Co-axial Introducer (Box of 10)
SHEATH NEEDLE
GAUGE x LENGTH
ECHOGENIC
STIFFNESS
DILATOR
LOCKING NUT
COLOR
GUIDEWIRE
CATALOG # SIZE DIAMETER x LENGTH MATERIAL
391604300E 4F 21G x 7cm Yes Stiff White .018” x 40cm NT
391605000E 5F 21G x 7cm Yes Stiff White .018” x 40cm SS
391605300E 5F 21G x 7cm Yes Stiff White .018” x 40cm NT
391605400E 5F 21G x 7cm No Stiff White .018” x 40cm NT
Introducer Radial Sheath
IMRP15S
Structure
1(cm)21Volume(mL)15Pushpull
IMRP15 1 24.5 15 Pushpull
IMRP15L 1 27 15 Pushpull
IMRP15XL 1 29 15 Pushpull
IMRP20S 2 21 20 Pushpull
IMRP20 2 24.5 20 Pushpull
IMRP20L 2 27 20 Pushpull
IMRP20XL 2 29 20 Pushpull
YPR15S 1 21 15 Luer
YPR15 1 24.5 15 Luer
YPR15L 1 27 15 Luer
YPR15XL 1 29 15 Luer
YPR20S 2 21 20 Luer
YPR20 2 24.5 20 Luer